E-Z Integrated Key Cup 8 Panel Drug Test + AD
# EZ-DUA-187-013: Box of 25
(COC, THC, OPI, AMP, mAMP, PCP, BZO, BAR) + AD(OX, SG, PH)
Drugs Tested:
- Cocaine
- Marijuana
- Opiates
- Amphetamines
|
- Methamphetamines
- Phencyclidine
- Benzodiazepines
- Barbiturates
|
Features:
- Fast - Results in 1-3 minutes
- Easy - Collect urine and insert the drug card. The appearance of one line indicates a positive result, while two lines indicate a negative result.
- Dependable
- The E-Z Key Cup Drug Test has developed a reputation for providing quality and innovative products.
- Accurate
- Our tests are highly sensitive and specific.
- Inexpensive
E-Z Integrated Key Cup High points
99% Accurate
Test For Multiple Drugs
Split Specimen Drug Test
Specimen collector activates with key eliminating donor tampering
Label hides test result from those who do not need to view results.
Integrated drug test cup design eliminates handling
Cut-offs levels of drug testing set according SAMHSA
Description Of Product:
The E-Z Integrated Split Key Cup is an instant response drug-testing device that eliminates urine handling and donor tampering, by providing an efficient and unique approach for onsite testing. Split Key Cup is a one step on-site urine drug test device, which gives 99% of accuracy and results quickly in few minutes. It offers a compact and split specimen format, which is easy to test and administer for both male and female.
Integrated drug test cups do not require the examiner to come in contact with the urine specimen. The E-Z Integrated Split Key Cup is also called: E-Z Key Cup, E-Z Integrated Cup, E-Z Split Cup, E-Z Integrated Split Key Cup or Integrated Key Cup. Most of our customers call it "ez cup", or just "Key Cup". It helps to discard the possibility of contaminating the specimen. The E-Z Split Key Cups are a widely used drug test device, as they are available at low cost and are convenient and easy to
use. They are also fast and accurate with results in minutes. Positive Test results should be confirmed with a SAMHSA certified laboratory.
The E-Z integrated Split Key Cup Testing Process:
The E-Z Split Specimen testing process is simply taking the urine specimens during the collection process. The Split Key cup has a key that moves into the side of the cup. It doesn’t need to turn for starting, just have to insert the key to start. In this method the urine specimen is divided into two containers. Then urine deluges the test chamber parting
without touching the specimen. If the result of the test reports positive, the test cup have to be sent to laboratory with the rest of the specimen untouched for GC/MS confirmation. The trigger system operates the patent key on the test cup, which prevents donor activation and tampering and the test is maintained under the collector’s control. Some states demand E-Z specimen drug testing as a mandatory procedure. The Integrated Key Cup also has an advantage that when the specimen is placed in the cup, the examiner can record the reading of the temperature strip. Then the test will be activated and kept aside, later it can be read up to 1 hour. It gives more control for examiner over the test and enables to perform the test after the donor leaves the testing site.
The E-Z test cup detects multiple drugs existence, as accurate as the laboratory tests in few minutes. The E-Z Integrated Split Key cups are available in various combinations from 3 panel to 12 panel test cups E-Z Key 3, E-Z Key 4, E-Z Key 5, E-Z Key 6, E-Z Key 7, E-Z Key 8, E-Z Key 9, 10, and 12 panel urine drug test cups.
PRINCIPLE
The E-Z key cup is an immunoassay based on the principle of competitive binding. Drugs which may be present in the urine specimen compete against their respective drug conjugate for binding sites on their specific antibody. During testing, a urine specimen migrates upward by capillary action. A drug, if present in the urine specimen below its cut-off concentration, will not saturate the binding sites of its specific antibody. The antibody will then react with the drug-protein conjugate and a visible colored line will show up in the test line region of the specific drug strip.
The presence of drug above the cut-off concentration will saturate all the binding sites of the antibody. Therefore, the colored line will not form in the test line region. A drug-positive urine specimen will not generate a colored line in the specific test line region of the strip because of drug competition, while a drug-negative urine specimen will generate a line in the test line region because of the absence of drug competition. To serve as a procedural control, a colored line will always appear at the control line region, indicating that proper volume of specimen has been added and membrane wicking has occurred.
REAGENTS
The Integrated key cup contains a membrane strip coated with drug-protein conjugates (purified bovine albumin) on the test line, a goat polyclonal antibody against gold-protein conjugate at the control line, and a dye pad which contains colloidal gold particles coated with mouse monoclonal antibody specific to the drugs being tested.
QUALITY CONTROL
A procedural control is included in the Integrated key cup. A red line appearing in the control region (C) is considered an internal procedural control. It confirms sufficient specimen volume, adequate membrane wicking and correct procedural technique. Control standards are not supplied with this kit. However, it is recommended that positive and negative controls be tested as good laboratory practice to confirm the test procedure and to verify proper test performance.
Accuracy
A side-by-side comparison was conducted using the Integrated key cup and commercially available drug rapid tests. Testing was performed on approximately 300 specimens per drug type previously collected from subjects presenting for Drug Screen Testing. Presumptive positive results were confirmed by GC/MS. The following compounds were quantified by GC/MS and contributed to the total amount of drugs found in presumptive positive urine samples tested.
Forty (40) clinical samples for each drug were run using each of The Integrated key cup by an untrained operator at a Professional Point of Care site. Based on GC/MS data, the operator obtained statistically similar Positive Agreement, Negative Agreement and Overall Agreement rates as trained laboratory personnel.
Precision
A study was conducted at three physician offices by untrained operators using three different lots of product to demonstrate the within run, between run and between operator precision. An identical panel of coded specimens, containing drugs at the concentration of ± 50% and ± 25% cut-off level, was labeled, blinded and tested at each site.
Fifteen (15) urine samples of normal, high, and low specific gravity ranges (1.000-1.037) were spiked with drugs at 50% below and 50% above cut-off levels respectively. The Integrated key cup was tested in duplicate using fifteen drug-free urine and spiked urine samples. The results demonstrate that varying ranges of urinary specific gravity does not affect the test results.
Effect of the Urinary pH
The pH of an aliquoted negative urine pool was adjusted to a pH range of 5 to 9 in 1 pH unit increments and spiked with drugs at 50% below and 50% above cut-off levels. The spiked, pH-adjusted urine was tested with the Integrated key cup. The results demonstrate that varying ranges of pH does not interfere with the performance of the test.
Cross-Reactivity
A study was conducted to determine the cross-reactivity of the test with compounds in either drug-free urine or drug positive urine containing drugs of abuse.
Integrated E-Z
Split Key Cup Product Procedure
E-Z KEY CUP PACKAGE CONTENTS
Remove the key by twisting it from the center of the cup cap. Open cap with
the Pull Tab
(key is held by technician)
Donor provides specimen and secures cap. Note: Secure cap by pressing down on
the Pull Tab until an audible click is heard
Check cap for tight seal. Technician dates and initials the security seal and
places security seal over cap
On a flat surface, technician inserts key and pushes in
Peel off the label to view results
If the test cup includes S.V.T., read adulteration test results between 3 -
5 minutes
Read drug test results at 5 minutes
A photocopy of the drug test results can be made by placing the entire cup with
the card face down on the
copier / scannerr